Triflex ProPark certification and approvals

BBA

British Board of Agrément certified no. 13/5051 Product sheet 2

Durability – under normal service conditions, the system will have a service life in excess of 15 years.

Download Certificate

ETAG 005

European Technical Approval Guideline 005 Liquid Applied Roof Waterproofing Kits.

Highest classification in all test criteria:

  • Working life: W3 (25 year durability)
  • Climatic zones: M and S (Moderate to Severe)
  • Imposed loads: P1 to P4 (Low to Special)
  • Roof slope: S1 to S4 (<5% to >30%)
  • Minimum surface temperature: TL4 (down to -30°C)
  • Maximum surface temperature: TH4 (up to +90°C)
  • Resistance to wind loads >50 kPa
  • Statement on dangerous substances - none contained
  • External fire performance Class BROOF (t1), BROOF (t2), BROOF (t3), BROOF (t4)
  • Reaction to fire Euroclass E

ETA certification under ETAG 005 includes crack bridging tests under TR008 ‘Determination of the resistance to fatigue movement’ which tests cyclic crack bridging ability from 0mm to 2mm at -10°C. To achieve the W3 (25 year durability) statement under the ETA, the system has successfully undergone this testing for 1,000 cycles.

ETA 04/0019 (Triflex ProTerra®) Note: Triflex ProPark® is a rebranded version of Triflex ProTerra.

EN 1504-2

EN 1504-2:2004 Products and systems for the protection and repair of concrete structures. Definitions, requirements, quality control and evaluation of conformity. Surface protection systems for concrete, certified.

Triflex ProPark

Essential characteristics Performance
Abrasion resistance weight loss < 3000 mg < 3000 mg
Permeability to CO2 SD > 50 m
Water vapour permeability class II class II
Permeability to water w < 0.1 kg/m² x h0.5
Thermal compatibility ≥ 2.0 (1.5) N/mm²
Resistance to severe chemical attack reduction in hardness class1, 3 d without pressure
Crack bridging ability B 4.2 (-20°C)
Impact resistance class I
Adhesion strength by pull off test ≥ 2.0 (1.5) N/mm²
Reaction to fire class Bfl-S1
Skid resistance class III
Impact resistance class I

Dynamic Crack bridging ability under EN 1504-2 is determined using EN 1062-7:2004 Paints and varnishes. Coating materials and coating systems for exterior masonry and concrete. Determination of crack bridging properties. Achievement of B 4.2 (-20°C) crack bridging ability is based on:

  • Application to a concrete substrate with a formed crack inducer / weak point. The concrete is then broken to simulate a crack occurring post installation (from nothing);
  • The crack is opened from 0.2mm to 0.5mm over a period of 6.66 seconds, and over the next 10 seconds the crack is rapidly cycled from 0.5mm to 0.55mm to 0.45mm to 0.55mm for 10 cycles finishing at 0.5mm. The crack is then closed from 0.5mm to 0.2mm over a period of 6.66 seconds and over the next 10 seconds the crack is rapidly cycled from 0.2mm to 0.25mm to 0.15mm to 0.25mm for 10 cycles finishing at 0.2mm;
  • The complete cycle takes 33.32 seconds which for the 1,000 full cycles takes 9.25 hours in total per test. The total number of crack cycles is 21,000: 1,000 larger movements to simulate building movement from 0.2mm to 0.5mm, and 20,000 smaller movements to simulate loads (10,000 between 0.45mm and 0.55mm and 10,000 between 0.15mm and 0.25mm). Once the testing is complete the waterproofing is evaluated using a coloured water column for 24 hours.

FLL

FLL ‘Green Roof Guidelines - Guidelines for the Planning, Construction and Maintenance of Green Roofs’ certified

  • Root and rhizome resistant

Heat resistant

Tested for resistance to high temperature asphalt overlay (250°C)

Anti-skid resistance

Anti-skid tests carried out wet on new indicative samples in accordance with UKSRG Guidelines (2016)

With 0.7 - 1.2mm Triflex Quartz:

  • PTV approx. 75 (Four S rubber / Slider 96)
  • PTV approx. 68 (TRRL rubber / Slider 55)

With 1.0 - 3.0mm Triflex Emery:

  • PTV approx. 80 (Four S rubber / Slider 96)
  • PTV approx. 77 (TRRL rubber / Slider 55)

Fire performance

  • BS 476-3 (EXT.F.AA)
  • EN 13501-5: Class BROOF (t4)
  • EN 13501-1: Class Bfl-s1

EN 13501-5

EN 13501-5:2016 Fire classification of construction products and building elements. Classification using data from external fire exposure to roofs tests certified.

  • BS EN 13501-5 : 2005 as European Class BROOF(t4)

EN 13501-1

EN 13501-1:2018 Fire classification of construction products and building elements. Classification using data from reaction to fire tests certified:

  • Class Bfl-s1

BS 476-3

In Accordance With The Designations Defined In BS 476: Part 3: 2004 The Test Specimens Are In Category “EXT.F.AA”.

Manufacturer certification

  • ISO 9001 Quality Management
  • ISO 14001 Environmental Management
  • ISO 50001 Energy Management